System Overview

The Light Counter system is a precision light integrator system for photographers who work with ultraviolet (UV) printing processes such as platinum/palladium, carbon, cyanotype and gum. The system allows photographers to make accurate and repeatable exposures when printing.

Light Counter is designed as a flexible system. The basic configuration has a light integrator and a UV sensor. Advanced users can add additional peripheral devices to support their specific needs.

The system components are:

  • The Light Integrator
  • UV Sensors
  • Temperature Sensors
  • Power Controller

The system is designed by a photographer for photographers. It works simply and quickly, with a strong emphasis on ease of use.

The Light Integrator

The light integrator is “the brain” of the system. It controls the exposure, and all peripheral sensors and devices. It continually samples the UV intensity, and automatically adjusts the exposure time to allow for lamp warm-up and any fluctuations in the power supply.

LC3 light Integrator

The LC3 (second generation) light integrator has a large 4.3” TFT display with a capacitive touch screen (using the same technology as your mobile phone or tablet computer). This allows incredibly easy set-up and control. It supports up to four sensors (UV or temperature), so you can monitor exposure in every part of your UV printing unit. It stores up to eight exposure presets, for fast switching between your favourite printing variations.

The LC2 (first generation) light integrator supports a single UV sensor and a single temperature sensor. It has a smaller display, and is controlled with buttons rather than a touch screen.

LC2 kits are only available while stocks last.

Both generations feature an automated calibration process, ensuring that your exposures are consistent even if you move the sensors.

Both generations support a power controller device that will switch your UV light source on and off as required. The system also works without the power controller, of course: you just have to switch the light source on and off yourself.

UV Sensors

Two versions of the UV sensor are available. The standard version has a 365nm narrowband filter installed to optimise the sensor for iron-based printing processes. A broadband version without the filter is available by request.

Second Generation UV Sensor

The second generation sensors are designed to work with the LC3 light integrator. They have a new design which is optimised for maximum precision. They are factory calibrated to eliminate variability in sensor sensitivity. Many optoelectronic components have as much 25% variance in their sensitivity. This design reduces that to a couple of percent.

First generation UV sensors designed for the LC2 light integrator continue to work with the LC3 light integrator, albeit without the advanced features introduced with the second generation sensor.

Temperature Sensors

The temperature sensor monitors the temperature inside your UV printing unit. This allows you to be confident that you are not over-heating your prints during exposure.

The second generation sensors are about 25% smaller than the first generation. This allows them to fit easily into smaller spaces.

First generation temperature sensors designed for the LC2 light integrator continue to work with the LC3 light integrator.

Power Controller

The power controller is an add-on device that allows the light integrator to switch the UV light source on and off. This brings extra convenience and a small increase in exposure accuracy.

Two versions of the power controller are available. The standard power controller (first generation) can switch loads up to 5A, which is approximately 1100W in Europe, and 550W in the USA. This is sufficient for most photographers’ UV light sources.

Standard Power Controller

The professional power controller (second generation) has double the capacity: 10A which is about 2200W in Europe and 1100W in the USA. This is designed for high intensity professional light sources, especially high power LED systems.